technical data humidity

Humidity sensor PCE-P18 PCE Instruments

Technical data humidity sensor PCE-P18. Humidity. Measuring range: 0 100 %RH: Accuracy: ± 2 % (for range of 10 % . 90 % RH) ± 3 % (residual range) Hysteresis: ± 1 % RH: Temperature. Measuring range 20 60 °C: Accuracy: ± 0.5 % of measuring range: Temperature influence: ± 25 % / 10 °C: Output humidity

Read More
Technical Data Sheet: Humidity Indicator Card

2014-12-11 · Humidity Indicator Cards (HIC’s) are printed with moisture sensitive spots which respond to levels of humidity with a visible color change from blue to pink. The humidity inside dry packed barrier Technical Data Sheet: Humidity Indicator Card Wisepac Active Packaging Components Co., Ltd.

Read More
Technical Data downloads.epluse

2015-12-10 · Technical Data Humidity Sensors for HVAC Applications Nominal capacitance C 76 (at 20°C / 68°F) 200 ± 30 pF Sensitivity 0.6 pF / % RH Working range Humidity 10...95% RH Temperature -40...110°C (-40...230°F) Linearity error (20...90% RH) < ± 2% RH Hysteresis 2.0 ± 0.3% RH Response time t 90 < 15 sec

Read More
RELATIVE HUMIDITY SENSOR HS 1100 / HS 1101

2005-2-3 · TECHNICAL DATA1 RELATIVE HUMIDITY SENSOR HS 1100 / HS 1101 Based on a unique capacitive cell, these relative humidity sensors are designed for high volume, cost sensitive applications such as office automation, automotive cabin air control, home appliances, and industrial process control systems. They are

Read More
RELATIVE HUMIDITY MODULE HM 1500

2005-2-3 · TECHNICAL DATA1 RELATIVE HUMIDITY MODULE HM 1500 Based on the rugged HS1101 capacitive humidity sensor, HM1500 is a dedicated humidity transducer designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a micro-controller is made possible with the module’s linear voltage output. MAIN FEATURES

Read More
DIGITAL HUMIDITY SENSOR HYT-221

2012-8-28 · Technical Data Humidity Measurement Humidity measuring range (1) 0 100% rH see Figure 3 Humidity accuracy (2) (Maximum tolerance) ±1.8% rH (0 80% rH) see Figure 1 Accuracy humidity 0 .. 10% RH (0 50 ° C) (Typical tolerance) ±(1% rF + 8% aw) aw = rF / 100% Reproducibility (3) ±0.2% rH Hysterisis < ±1% rH Humidity resolution 0.02% rH

Read More
HUMICAPâ Handheld Humidity and period of time.

2017-10-18 · HM45 Technical Data Humidity Measurement Accuracy (Including Non-linearity, Hysteresis, and Repeatability): At 0 +40 °C At -40 0 °C and +40 +60 °C ±1.5 %RH (0 90 %RH) ±2.5 %RH (90 100 %RH) ±3.0 %RH (0 90 %RH) ±4.0 %RH (90 100 %RH) Humidity sensor HUMICAPâ 180R Temperature measurement range -40 +60 °C (-40 +140 °F)

Read More
DHT11 Humidity & Temperature Sensor

2019-5-17 · Step one: Keep the DHT sensor at the condi on of Temperature 50~60Celsius, humidity <10%RH for 2 hours; Step two:K keep the DHT sensor at the condi on of Temperature 20~30Celsius, humidity >70%RH for 5 hours. (4) Temperature ect. Rela ve humidity largely depends on temperature.

Read More
Product info sheet no. C 4.4 Humidity/-temperature

2018-1-16 · Use of capacitive MELA®-humidity sensor elements is a guarantee of: high long-term stability almost linear characteristic curve good dynamic performance resistance to dew formation small hysteresis. Technical data Humidity measuring range .. 0...100%rh

Read More
ALMEMO D6 Air humidity Ahlborn

2021-3-4 · Technical data High-precision sensor for temperature, humidity, atmospheric pressure FHAD 36 RHK Hand-held sensor for temperatures up to +170 °C Automatic atmospheric pressure compensation, Digital sensor with ALMEMO® D6 plug General description and common technical data FHAD 36 Rx (see page 08.11)

Read More
Technical Data Sheet: Humidity Indicator Card

2014-12-11 · Humidity Indicator Cards (HIC’s) are printed with moisture sensitive spots which respond to levels of humidity with a visible color change from blue to pink. The humidity inside dry packed barrier Technical Data Sheet: Humidity Indicator Card Wisepac Active Packaging Components Co., Ltd.

Read More
RELATIVE HUMIDITY MODULE HM 1500

2005-2-3 · TECHNICAL DATA1 RELATIVE HUMIDITY MODULE HM 1500 Based on the rugged HS1101 capacitive humidity sensor, HM1500 is a dedicated humidity transducer designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a micro-controller is made possible with the module’s linear voltage output. MAIN FEATURES

Read More
HUMICAPâ Handheld Humidity and period of time.

2017-10-18 · HM45 Technical Data Humidity Measurement Accuracy (Including Non-linearity, Hysteresis, and Repeatability): At 0 +40 °C At -40 0 °C and +40 +60 °C

Read More
ALMEMO D6 Air humidity Ahlborn

2021-3-4 · Technical data High-precision sensor for temperature, humidity, atmospheric pressure FHAD 36 RHK Hand-held sensor for temperatures up to +170 °C Automatic atmospheric pressure compensation, Digital sensor with ALMEMO® D6 plug General description and common technical data FHAD 36 Rx (see page 08.11)

Read More
Room Sensor CO₂ / Humidity / Temperature

2020-11-6 · Technical data and operation instructions are shown in the ZIP-BT-NFC data sheet. Wiring diagram GND = 1 AC/DC 24 V = 2 MP Bus = 5 Output Temperature = 8 Output Humidity (22RTH / 22RTM) = 9 GND = 10 Digital Input, e.g. presence detector = 12/13 Output CO₂ (22RTM) = 14 GND = 15 Digital input NFC connection

Read More
Technical note TN1218 Interpreting humidity and

2021-4-27 · The values stored are raw data, available as output from the ADC, so the user has to convert the data read from the registers to obtain the temperature in °C and the relative humidity in %. Figure 1. Humidity sensor analog-to-digital flow Interpreting humidity and temperature readings in the HTS221 digital humidity sensor TN1218 Technical note

Read More
Temperature and humidity Data Logger Log100 /

The Data Logger Log100 / 110 is ideal for the registry of the development of temperature in the the transport and storage sectors. The data logger is also used for the control of temperature in multiple sectors. For more specific applications we have the data logger Log110 that registers in addition the development of relative humidity. Both data logger are an economic solution for the

Read More
Molded Case Circuit Breaker Specifications Technical Data

2016-2-6 · Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Dry heat (60086-2-2) 100 °C, relative humidity <50 %, 7 days Moisture heat (60068-2-3) 40 °C, relative humidity 93 %, 56 days Site Altitude [m] to 2000 N.N. Protection Class IP2X, when wired

Read More
TECHNICAL DATA SHEET Farnell element14

2019-11-13 · Working Humidity ≤80%RH Temperature and humidity of storage [email protected]≤95%RH Certificate CE/ERP/ROHS. Page <2> 07/12/19 V1.0 TECHNICAL DATA SHEET T8 LED Linear Fixture Model PEL01612 614 TECHNICAL DATA SHEET T8 LED Linear Fixture Model PEL01615 617 Important Notice :

Read More
ASHRAE Technical FAQ

ASHRAE Technical FAQ ID 103 Question What temperature and relative humidity level does ASHRAE recommend for data communication (datacom) facilities? Answer ASHRAE Technical Committee 9.9 publishes a series of books and design guides related to the application. Information on TC 9.9’s Datacom Series is available on the ASHRAE website.

Read More